国精产品一区二区三区有限公司_女人与拘的交酡过程_国产日韩欧美一区二区东京热_欧美毛片又粗又长又大电影

    Products?Cable entry systems for railway technology

Cable entry systems for railway technology

Fire resistance of fire barriers according to EN 45545-3 (E45/EI30)

 

The European railway standard for fire safety EN 45545-3 regulates the fire resistance of fire barriers. The requirements and measures defined in this part of the standard aim to protect passengers and staff in trains against onboard fire incidents. icotek cable entry systems meet the classifications E45 and EI30. Find out more ?

icotek cable entry systems at a glance


Filter products:

Split cable entry frame, IP66 / UL Type 12/4X*

Grommet based cable entry with IFPS fire penetration seals acc. to EN 45545-3 for standard cut-outs of heavy industrial connectors. Available as single or double row version.

? KEL-ER-BS

Split cable entry frame, IP54 / UL Type 12

Grommet based cable entry frames with IFPS fire penetration seals acc. to EN 45545-3 suitable for cut-outs of heavy industrial connectors. Available as single or double row version.

? KEL-U-BS

Heavy duty cable entry plate, IP66/IP68 / UL Type 12/4X*

Heavy duty cable entry plate with IFPS fire penetration seals acc. to EN 45545-3.

? KEL-DPU-BS

Cable entry plates, high cable density, IP66 / UL Type 12

Cable entry plates for standard cables with IFPS fire penetration seals acc. to EN 45545-3.

? KEL-DPZ-BS

Fire penetration seals, single

Fire penetration seals for certified icotek BS cable entry components, approved for use in railway technology.

? IFPS

Safe and fire protective cable routing in rolling stock and railway infrastructure

Duration: 24 min.

Sealing of conduits, pipes or cables according IP ratings up to IP 68 / UL Type 4X and railway standards EN 45545-2

Discover how to upgrade the system into a fire barrier according EN 45545-3

Shock and vibration proof cable management according EN 61373

Watch now!
 

Fire barriers can have different standards:

The lowest standard “E”

Barrier against flames, preventing fissure formation. "E45", for example, means that the specimen can withstand the test for 45 minutes.

The highest standard “EI”

Barrier against flames, preventing fissure formation and thermal insulation, which means that the temperature on the side facing away from the fire must not exceed 392° F (180° K above room temperature). "EI30", for example, means that the specimen can withstand the test for 30 minutes. 

Based on the standards EN 45545-3 and EN 1363-1 icotek cable entry systems have been tested on "E" and "EI" in vertical alignment using mounted IFPS fire penetration seals. All tested products have been successfully certified using only one layer of fire penetration seals. Furthermore, conventional cables instead of fire-resistant railway cables have been used for the testing.

icotek cable entry systems meet the classifications E45 and EI30!

 

Well tested & certified

Numerous certifications (IP, UL Type Rating according to UL50E, UL recognised,...) make icotek a reliable partner for railway technology. Due to the high quality of icotek products, good fire protection can be achieved according to EN 45545-2 in the category HL3 (Hazard Level 3) and EN 45545-3 (E45 and EI30). Furthermore, numerous icotek products have been subjected to a vibration and shock test according to EN 61373 with positive results. Certificates or declarations of conformity can be requested directly from us.